This paper details a geotechnical
site characterization for its applicability to accommodate heavy structural
loads in Sekondi-Takoradi, Ghana. The goal of the investigation, according to
the paper’s abstract, is as follows:
“The investigation focused on evaluating the engineering
integrity, shear strength, and ultimate bearing capacity of the foundation
soils to support heavy structural loads. Additionally, the study aimed to
delineate critical subsurface anomalies, weak zones, and adverse geological
structures that could compromise structural stability or threaten foundation
longevity.”
Basic site characteristics are shown below.
The investigation also relied on
geophysical surveys, including resistivity imaging and acoustic surveys. The
investigation also revealed, “weak lateritic soils often
associated with seepage paths that are recognised as near-surface fractures or
joints in the areas.” Those areas were found to have negative impacts on the
load-bearing capacity of the subsurface.
The proposed site was designated
for the satellite faculty of SRID, Ghana, at Sofokrom (a suburb of Essikado).
The site is in a tropical, coastal area with some topographic relief, not too far above sea level, but
with hilly areas as well. Some of its characteristics are shown above.
The geologic setting involves a
crystalline basement overlain unconformably by a sedimentary rock sequence
consisting of sandstones and shales.
“The sedimentary environment has been interpreted to be
of non-marine to coastal marine facies. It was postulated that Paleoweathering
in the source area, therefore, is one of the most important processes affecting
the composition of sedimentary rocks.”
The electrical resistivity imaging
(ERI) survey involved employing a dipole-dipole array. These are typically used
for subsurface thickness, rock structure, groundwater flow and aquifer,
groundwater salinity investigations as well as in the oil & gas industry to
determine formation water characteristics. The vertical electric sounding (VES)
survey was used for subsurface lithologic characterization. VES was done before
ERI and was conducted in different features of the terrain, such as hilly areas
and depressions, as well as flat areas. A key goal was to identify weak zones
where hydrologic seepage was prevalent so they could be avoided.
Several pits were dug to 1.5
meters, and samples were collected and sent to the lab to determine
geotechnical properties such as the Atterberg limits (liquid limit, plastic
limit, and plasticity index), particle size distribution, and the direct shear
strength. The liquid limit estimates the water content of fine-grained soils.
The plastic limit estimates the moisture content of the soil below which it
transforms from plastic to a semi-solid state. The plasticity index is “the
range of moisture content at which the soil is plastic and is the difference
between liquid limit and plastic limit values.” Particle size analysis was
performed with standard sieve techniques. The sieved particles were used to
determine the specific gravity of the samples. The direct shear test (DST)
procedure was done in two test pits of the most common terrain on the site, the
hilly terrain and the depressions. It is described below:
“In carrying out this test, a 60 mm × 60 mm cutting box
was driven into the undisturbed sample from the trial pits that is forced into
the experimental tube to obtain the sample for the test. The extracted sample
was carefully put into the shear box to ensure that the ring fitted properly
into the shear box apparatus. The gauge for the horizontal movement, vertical
movement, and proving ring was adjusted to the zero (2500) mark. The beam jack
was adjusted to be in contact with the lever-loading arm and the sample was
subjected to the normal loads of 2.1 kg, 4.2 kg, and 8.5 kg. A shear force was
then applied under each load and the shear stress was monitored until failure
occurred. The sample was unloaded and weighed. The sample was later placed in
the oven to dry and its dry weight was recorded. The procedure allows the
displacement under shear load, the proving ring reading and settlement dial
gauge to be recorded.”
The derived soil profiles, shown
below, showed “stiff, dry brown, loose, and shattered coarse-grained sand
silt mixtures” for the top meter with some gravel in a few pits.
The results of the Atterberg
Limits revealed the site was favorable for heavy loads, as described below:
“The relatively low liquid limits and plasticity indices
indicate soils with limited volume-change potential, thereby contributing to
favourable subgrade performance under anticipated loading conditions. These
consistency characteristics were considered together with the particle-size
distribution and soil classification in evaluating the engineering suitability
of the site.”
The particle size distribution
analysis revealed that the gravelly soils were the best substrate and the
silty-sandy soils were rated as a fair substrate, as described below:
“Based on the AASHTO and USCS classification systems,
soil samples from trial Pits 1, 2 and 3 are classified as A-2-6 (GC),
indicating gravelly soils with clay fines that are generally considered good
subgrade materials because of their relatively low plasticity, high gravel
content and favourable engineering characteristics. In contrast, trial Pits 4
and 5 are classified as A-2-4 (GM), representing silty gravel soils that are
considered fair subgrade materials owing to their comparatively higher sand content
and lower cohesion. The engineering assessment of subgrade quality was
therefore based on the combined interpretation of the USCS classification,
AASHTO classification, particle-size distribution, plasticity characteristics
and direct shear strength results rather than on a single engineering parameter.”
The direct shear test results
indicated competent substrate at some pits and less competent substrate at
others, suggesting different foundation designs would be required for the less
competent areas. A summary of the geotechnical and geophysical investigations
is given below.
“In all, the integrated geophysical and geotechnical
investigations indicate that the site is generally underlain by competent
subsurface materials capable of supporting civil infrastructure. However,
localized depressions, fractured zones and areas of elevated moisture content
may adversely affect foundation performance. Accordingly, foundation selection
should be site-specific, with shallow foundations being suitable in competent
areas, while localized ground improvement or deeper foundation systems may be
required within weaker zones identified by the integrated investigation.”
Overall, the site was found to be competent for supporting the heavy loads anticipated in the project, with some foundation design amendments in less competent areas. Composite results of the investigation for each of the five pits are shown in the columns below.
Figure 30. Columnal presentation of the geo-parameters for the lithologic sequence in the study area.
References:
Integrated
Geophysical and Geotechnical Site Characterisation for Civil Infrastructure
Development in Sekondi-Takoradi, Ghana. Asare Asante-Annor, Ernest Nyamekye Addo,
Kwaku Raymond Frimpong, and Gbenga Moses Olayanju. Open Journal of Geology. Vol.16
No.7, July 2026. Integrated Geophysical and
Geotechnical Site Characterisation for Civil Infrastructure Development in
Sekondi-Takoradi, Ghana